Circuit preparation - A check must be undertaken to ensure that the spray devices are correctly installed and that all fittings, probes, etc. are fixed in place. The equipment must be clean and free from residues and films, especially oils and greases. Prior to the application of the Riboflavin solution, rinse the machine with water and allow the equipment to dry completely. In case if a Pressofiltro, remove the filtering element. - Install a suitable circuit with centrifugal pump, water tank, piping, valves and instruments. The flow and the head of the centrifugal pump have to be suitable for the machine size. If possible insert a flowmeter on the pump outlet. Test results The visual absence of Riboflavin will constitute a test success, any visually detected Riboflavin will constitute a test failure. The results of the test are fully documented on a dedicated form. Instruments The necessary instruments are:
|
|||||||||